Start your marine air conditioner with soft start

Compressor starting current will be reduced by MBC soft-start device by approximately 50%. 

Connecting the MBC air conditioner control box to Soft Start is quite simple and requires no special setting.

MBC Soft Starter 

The MBC Easy Start enables the operation of any air conditioner using a lower voltage power source, eliminating the need for a larger or additional generator. It significantly reduces the compressor’s start current, making it an exceptional, custom-developed soft starter for single-phase motors. Utilizing a four-part self-optimizing start ramp sequence, it achieves the lowest possible start-up current.

This makes the MBC Soft Start the ideal solution for operating an air conditioner with a generator or inverter with limited utility power. It is housed in a fully weatherproof and flameproof in metal box with powder coated enclosure, ensuring durability and safety. The MBC Soft Start is CE certified and available in various sizes to suit different applications.

Generator start up load issues?

Not a problem anymore!

Start Your Marine AC Without Buying a Second or Bigger Generator or Inverter! 

Simply Installing a MBC Soft Start to minimize the starting load on your Genset.

GENERATOR START UP LOAD ISSUES?
NOT A PROBLEM ANYMORE!

Start Your Marine AC Without Buying a Second or Bigger Generator or Inverter! Simply Installing a MBC Easy Start to minimize the starting load on your Genset.

MBC Soft Starter

Starting booster, Easy Start!

START YOUR MARINE AIR CONDITIONER WITH EASY START

Compressor starting current will be reduced by Easy Start (MBC soft-start device) by approximately 50%. Connecting the MBC air conditioner control box to Easy Start is quite simple and requires no special setting.

Screenshot 2022 11 01 at 9.35.25
Screenshot 2022 11 01 at 9.35.32

RUNNING AIR CONDITIONERS ON INVERTER POWER

A 3500 BTU air conditioner needs a 1500W or bigger inverter to run using batteries. For a 8000 BTU model a 2500 W inverter must at least be used. For both models MBC Easy Starter is not necessary. On the contrary a 10000 or 13000 BTU model Require a 2500 W inverter (at least) and East Starter.

MBC Soft Starter
Unit Parameters
SDC 12-7000
SDC 24-7000
SDC 24-12000
SDC 48-16000
Power Supply
Ph/V/Hz
DC12V
DC24V
DC24V
DC48V
COOLING
Capacity
BTU/h
7000
7000
12000
16000
Rated power
kW
0.45
0.56
0.72
0.96
Rated current
A
35
23
30
20
HEATING
Capacity
BTU/h
8000
8500
13000
17000
Rated power
kW
0.54
0.6
0.8
1.2
Rated current
A
45
25
35
25
Seawater flow
m3/h
0.55
0.6
0.9
1.2
Air flow
m3/h
350
350
450
600
Dehumidification
L/h
0.8
1.0
1.2
1.8
Noise level
dB(A)
50
less 50
50
55
Width
mm
400
400
480
500
Height
mm
280
280
300
340
Depth
mm
240
240
285
513
Weight
kg
18
18
23
31
Refrigerant type
R134A
R134A
R134A
R134A
Air duct Diameter
mm
100
100
125
150
Sea water pipe Diameter
mm
16
16
16
16
More data